Composition and performance:
A quick-drying one-component anticorrosive primer composed of chlorosulfonated polyethylene resin, reinforcing resin, plasticizer, red iron oxide, mica red iron oxide, chemical anti-rust pigment, filler, etc.
The paint film has excellent resistance to salt spray, acid, alkali, salt, seawater and weathering.
The paint film has excellent resistance to chemical atmosphere and oil
The paint film dries quickly, is easy to apply, and can be applied at low temperatures
use:
Applicable to protective coating of steel structures and facilities such as pipelines, pipelines, storage tanks, support buildings, etc. in petrochemical, metallurgical, energy and other industries
Applicable to protective coating of concrete surfaces such as brick towers, cement walls, sewage pools, etc.
Technical indicators:
project | Performance Indicators | |
color | Iron oxide, gray, red lead | |
Status in the container | After stirring and mixing, there is no hard lump and it is in a uniform state | |
Construction | Barrier-free application | |
Coating appearance | Smooth | |
Gloss (60°)/°, ≥ | 25 | |
Fineness/μm, ≤ | 40 | |
Drying time/h, ≤
| Touch Dry | 1 24 |
Get down to business | ||
Flow time (ISO 6 cup)/s, ≥ | 90 | |
Non-volatile matter/%,≥ | 60 | |
Hiding power/(g/ ㎡ ), ≤ | 80 | |
Impact resistance/cm | 50 | |
Flexibility/mm | 1 | |
Cross-cut test/level | 1 | |
Salt water resistance (3% NaCl solution, 120h ) | No abnormality, no rust, no falling off | |
Alkali resistance (0.5% NaOH solution, 120h) | No abnormality, no shedding |
Construction instructions:
Single component can be used directly, add 10-20% chlorosulfonated polyethylene diluent, and apply by high-pressure airless spray, brush or roller.
Surface treatment:
The steel surface treatment is carried out in accordance with the national standard "Surface rust grade and rust removal grade of steel before painting" GB8923-88. Sandblasting rust removal reaches the national standard Sa2.5 grade, and manual rust removal reaches St3 grade.
Notes:
1. The paint should be stored in a low temperature, ventilated and dry place; away from fire and heat sources; the shelf life is one year in a cool and dry place.
2. The above information is written based on actual testing and usage experience of our company's technical personnel and can be used as a construction guide. However, due to differences in coating environments and supporting solutions, it is recommended that users conduct preliminary experiments and tests based on actual needs and uses before confirming use. Our company only guarantees the quality and stability of this product itself.
If you have any questions, please contact us promptly and we will answer your questions as soon as possible.