Composition and performance:
As a military technology, this achievement is now widely used in engineering vehicles, surveying and mapping vehicles, transport vehicles, hazardous chemicals carriages, etc. It has the characteristics of strong adhesion, good weather resistance, long life, acid and alkali resistance, humidity and heat resistance, salt spray resistance, and ultraviolet light resistance of general anti-corrosion coatings, and has the characteristics of super hardness, scratch resistance, high-intensity radiation resistance, high heat reflection, and high heat barrier. It is a new type of special coating that integrates anti-corrosion, heat insulation, cooling and heat preservation. The coating consists of an anti-corrosion primer, a heat-insulating mid-coat, and a heat-reflecting topcoat. Depending on the color, the internal environment temperature drops by 10-20℃, and the internal environment temperature drops by 8-15℃.
Technical indicators:
(1) Main performance indicators of anti-corrosion primer:
project | Performance Indicators | |
color | Iron red, gray | |
Status in the container | After stirring and mixing, there is no hard lump and it is in a uniform state | |
Construction | Trouble-free application | |
Coating appearance | Smooth paint film | |
luster | Flat light | |
Fineness/μm, ≤ | 40 | |
Drying time/h, ≤
| Touch Dry | 1 24 |
Get down to business | ||
Non-volatile matter/%,≥ | 65 | |
Impact resistance/cm | 50 | |
Bending test/mm | 1 | |
Cross-cut test/level | 1 | |
Salt water resistance (3% NaCl solution, 240h ) | No abnormality | |
Water resistance (120h) | No bubbling, no shedding, slight discoloration allowed | |
Salt spray resistance (240h) | No blistering, no peeling, no rusting |
(2) Main performance indicators of thermal insulation midcoat:
project | Performance Indicators | |
color | grey | |
Status in the container | After stirring and mixing, there is no hard lump and it is in a uniform state | |
Construction | Trouble-free application | |
Coating appearance | Smooth paint film | |
luster | Flat light | |
Fineness/μm, ≤ | 70 | |
Drying time/h, ≤
| Touch Dry | 1 24 |
Get down to business | ||
Non-volatile matter/%,≥ | 65 | |
Impact resistance/cm | 30 | |
Bending test/mm | 2 | |
Cross-cut test/level | 2 | |
Thermal conductivity λ/(w/mk), ≤ | 0.08 | |
Water resistance (120h) | No bubbling, no shedding, slight discoloration allowed |
(3) Main performance indicators of heat reflective coating:
project | Performance Indicators | |
color | Various | |
Status in the container | After stirring and mixing, there is no hard lump and it is in a uniform state | |
Construction | Trouble-free application | |
Coating appearance | The paint film is flat and smooth | |
luster | Matte, flat, high gloss | |
Fineness/μm, ≤ | 5 | |
Hardness (after complete drying), ≥ | 3H | |
Drying time/h, ≤
| Touch Dry | 1 |
Get down to business | 24 | |
Non-volatile matter/%,≥ | 55 | |
Impact resistance/cm | 50 | |
Bending test/mm | 1 | |
Cross-cut test/level | 1 | |
Reflectivity (ρ, wavelength 0.3-5μm)/≥ | 90 | |
Hemispherical emissivity (ε, wavelength 8-13.5μm)/≥ | 80 | |
Water resistance (120h) | No bubbling, no shedding, slight discoloration allowed |
Construction reference:
1. Before painting, the paint must be thoroughly stirred with a handheld electric stirrer to ensure construction quality and product performance. Accurately weigh components A and B according to the specified ratio and mix and stir evenly.
2. The prepared paint should be used up within 8 hours to avoid curing waste. Avoid construction under rainy conditions.
3. The primer needs to be sprayed twice, with a dry film thickness of 70-90 microns and an interval of more than 12 hours between each coat.
4. The thickness of the midcoat is required to be 100 microns, which can generally be achieved by spraying 1-2 coats, with an interval of more than 12 hours between each coat.
5. The topcoat thickness is required to be between 60-80 microns, and two coats are required, with an interval of more than 12 hours between each coat. The total film thickness is required to be around 260 microns.
Notes:
1. The paint should be stored in a low temperature, ventilated and dry place; away from fire and heat sources; the shelf life is half a year in a cool and dry place.
2. The above information is written based on actual testing and usage experience of our company's technical personnel and can be used as a construction guide. However, due to differences in coating environments and supporting solutions, it is recommended that users conduct preliminary experiments and tests based on actual needs and uses before confirming use. Our company only guarantees the quality and stability of this product itself.
If you have any questions, please contact us promptly and we will answer your questions as soon as possible.