Product

XW-H3611 High-efficiency heat shielding and cooling heat reflective deck paint

Composition and performance:

As a military technology, this achievement is now widely used in the cooling, rust prevention and corrosion protection of the outer surface of the ship hull deck. It has the characteristics of strong adhesion, good weather resistance, long life, acid and alkali resistance, moisture and heat resistance, salt spray resistance, and ultraviolet light resistance of general anti-corrosion coatings, and has the characteristics of super hardness, scratch resistance, high-intensity radiation resistance, high heat reflection, and high heat barrier. It is a new type of special coating that integrates anti-corrosion, heat insulation, cooling and heat preservation. The coating has good adhesion between the coatings and strong impact resistance. It can adapt to the thermal expansion and contraction caused by heavy load impact and environmental temperature difference, and will not crack or fall off after long-term use.

The paint consists of an anti-corrosion primer, a thermal insulation mid-coat and a heat-reflective topcoat. Depending on the color, the internal environment can be cooled by 10-20°C and the external environment by 8-15°C.


Technical indicators:

(1) Main performance indicators of anti-corrosion primer:

project

       Performance Indicators

color

                  Iron red, gray

Status in the container

After stirring and mixing, there is no hard lump and it is in a uniform state

Construction

Trouble-free application

Coating appearance

Smooth paint film

luster

Flat light

Fineness/μm, ≤

40

Drying time/h, ≤

                    

                       Touch Dry                    

1

24

   Get down to business

Non-volatile matter/%,≥

65

Impact resistance/cm

50

Bending test/mm

1

Cross-cut test/level

1

Salt water resistance (3% NaCl solution, 240h )

No abnormality

Water resistance (120h)

No bubbling, no shedding, slight discoloration allowed

Salt spray resistance (240h)

No blistering, no peeling, no rusting


(2) Main performance indicators of thermal insulation midcoat:

project

      Performance Indicators

color

                 grey

Status in the container

After stirring and mixing, there is no hard lump and it is in a uniform state

Construction

Trouble-free application

Coating appearance

Smooth paint film

luster

Flat light

Fineness/μm, ≤

70

Drying time/h, ≤

                    

                      Touch Dry                    

1

24

   Get down to business

Non-volatile matter/%,≥

65

Impact resistance/cm

30

Bending test/mm

2

Cross-cut test/level

2

Thermal conductivity λ/(w/mk), ≤ 

0.08

Water resistance (120h)

No bubbling, no shedding, slight discoloration allowed


(3) Main performance indicators of heat reflective coating:

project

      Performance Indicators

color

                 Various

Status in the container

After stirring and mixing, there is no hard lump and it is in a uniform state

Construction

Trouble-free application

Coating appearance

The paint film is flat and smooth

Gloss (60°)/°, ≥

90

Fineness/μm, ≤

5

Hardness (after complete drying), ≥

2H

Drying time/h, ≤

                    

                      Touch Dry                    

2

   Get down to business

24

Non-volatile matter/%,≥

55

Impact resistance/cm

50

Bending test/mm

1

Cross-cut test/level

1

Reflectivity (ρ, wavelength 0.3-5μm)/≥

90

Hemispherical emissivity (ε, wavelength 8-13.5μm)/≥

80

Water resistance (natural seawater, 27±6℃, 240h)

The paint film does not bubble, fall off or rust.

Salt spray resistance (2000h)

The paint film does not bubble, fall off or rust.

Artificial weathering resistance (1000h)

No cracks, slight discoloration and slight powdering are allowed

Weather resistance (24 months of exposure to ocean atmosphere)

No cracks, slight discoloration and slight powdering are allowed


Construction reference:

1. Before painting, the paint must be thoroughly stirred with a handheld electric stirrer to ensure construction quality and product performance. Accurately weigh components A and B according to the specified ratio and mix and stir evenly.

2. The prepared paint should be used up within 8 hours to avoid curing waste. Avoid construction under rainy conditions.

3. The primer needs to be sprayed twice, with a dry film thickness of 70-90 microns and an interval of more than 12 hours between each coat.

4. The thickness of the midcoat is required to be 100 microns, which can generally be achieved by spraying 1-2 coats, with an interval of 12 hours between each coat.

superior

5. The topcoat thickness is required to be between 60-80 microns, and two coats are required, with an interval of more than 12 hours between each coat. The total film thickness is required to be around 260 microns.


Notes:

1. The paint should be stored in a low temperature, ventilated and dry place; away from fire and heat sources; the shelf life is half a year in a cool and dry place.

2. The above information is written based on actual testing and usage experience of our technical staff and can be used as a construction guide.

However, due to the differences in coating environments and supporting solutions, it is recommended that users conduct trials and tests in advance according to actual needs and purposes before confirming use. The company only guarantees the quality and stability of this product itself.


Inquiry Now