Product

XW-2188 building exterior wall fluorocarbon paint

Composition:

Organic fluorine resin, high-quality pigments and fillers, imported additives, organic solvents, etc.

Features:

Service life of more than 15 years, strong weather resistance, corrosion resistance, durability, and temperature resistance. No stain, washability, strong self-cleaning properties. Waterproof, non-flammable, and mildew-proof. Divided into single-component and two-component packaging


Application:

Building cement walls, masonry structures, roof tiles, ceramic surfaces, etc.


Color:

According to color card or customer requirements.


Technical performance:

Project

Performance Indicators

Status in the container

After stirring and mixing, there is no hard lump and it is in a uniform state

Construction

Paint two layers of barrier-free

Coating appearance

Flat and smooth, the paint film has normal appearance

Fineness/μm,≤

25

Drying time/h,≤

Touch Dry

2

Practical

24

Adhesion (cross-hatch method)

1

Non-volatile matter:%

55

Impact strength,kg·cm

,50

Flexibility,mm

1

Washability

12000 times without showing bottom

Stain resistance

Reflection coefficient decrease rate ≤ 3%

Freeze-thaw resistance of coating

No blistering, no powdering, no cracking after 20 times

Water resistance

No blistering or peeling

Salt spray resistance (2000h)

No blistering or peeling

Sulfuric acid resistance (10%, 168h)

No blistering, no powdering, no rusting

Hydrochloric acid resistance (10%, 168h)

No blistering, no powdering, no rusting

Alkali resistance (10%, 168h)

No blistering, no powdering, no rusting

Weather resistance (3000h)

Slight loss of gloss and discoloration are allowed, but no powder loss



Construction Guide:

Before use, stir thoroughly and use according to the ratio marked on the trademark. Please use the paint supplier's thinner; dust, oil and other dirt attached to the wall must be cleaned before construction; the surface to be painted must be completely dry. The new cement is too alkaline, so it must be completely dried before construction. The wall moisture content is required to be less than 8% and the pH value is less than 10; the time interval between each layer of painting should not be less than 8 hours; it can be applied by brushing, rolling, spraying and other processes; the base coating must be applied with the company's all-purpose closed anti-alkali primer; the actual coverage rate will vary depending on the construction process, the roughness of the surface to be painted and the construction environment; if the construction surface has pits and unevenness, it is necessary to use the all-purpose closed anti-alkali primer to make putty and smooth it before construction.


Coating area:

Theoretical value Theoretical value is 6-9 square meters/kg·coat.


Storage period:

Cool and dry place, the shelf life is one year.


Notes:

1. The paint should be placed in a low temperature, ventilated, dry place, away from fire and heat sources. Work clothes, gloves and protective glasses must be worn during painting, and the construction should be carried out under well-ventilated conditions.

2. This manual is the accumulation of our practice and experience and can be used as a construction guide. Since the product use conditions are beyond our control, we are only responsible for the quality of the paint itself, and this manual does not contain any guarantee components.

Inquiry Now

If you have any questions, please contact us promptly and we will answer your questions as soon as possible.