Composition and performance:
Two-component paint composed of special acrylic resin, trace special modified resin, pigment filler, imported additives, special solvent and crosslinking agent
The paint film has excellent water resistance and shielding performance; excellent resistance to chloride ion penetration, salt spray resistance, oil resistance and chemical resistance, good weather resistance, dry-wet alternation performance and resistance to cold and heat changes; excellent cathodic protection compatibility, with moisture curing performance
Application:
Suitable for long-term heavy-duty anti-corrosion coating on the surface of steel and concrete components that are used for a long time and difficult to maintain in harsh environments such as the ocean, such as: surface coating of equipment and concrete components that are fully or semi-immersed in water
Technical indicators:
Project | Performance Indicators | |
Color | Various | |
Status in the container | After stirring and mixing, there is no hard lump and it is in a uniform state | |
Construction | Trouble-free application | |
Coating appearance | Normal | |
Luster(60°),≥ | 80 | |
Fineness/μm,≤ | 30 | |
Drying time/h,≤
| Touch Dry | 1 12 |
Get down to business | ||
Flow time (ISO 6 cup)/s,≥ | 90 | |
Non-volatile matter/%,≥ | 55 | |
Hiding power/(g/㎡), ≤ light color | 100 | |
Impact resistance/cm | 50 | |
Flexibility/mm | 1 | |
Pencil hardness (abrasions) | H | |
Cross-cut test/level | 1 | |
耐水性(72h) | No bubbling, no shedding, slight discoloration allowed | |
Heat resistance (90±2℃, 4h) | No bubbles, no wrinkles | |
Gasoline resistance (2h) | No foaming, no softening, no stickiness |
Construction instructions:
Main agent: curing agent = 5:1, stir evenly, add 10-15% of the matching diluent, and apply by high-pressure airless spray, brush or roller.
Substrate treatment:
Use electric tools or steel scrapers to remove loose mortar, debris and surface attachments on the surface of reinforced concrete, and use matching mortar or putty to fill the honeycombs and other depressions on the concrete surface and remove the oil on the surface. Finally, rinse the concrete surface with clean water to make it clean, tidy and flat.
Coating requirements:
1. After surface treatment, concrete components should be kept clean and dry and anti-corrosion primer should be applied in time.
2. Concrete components can generally be painted after 30 days of maintenance.
3. Brushing, rolling and spraying can be used for construction.
4. The painting interval is generally controlled within 24 hours. If the interval is too long, it is recommended to roughen the surface to be painted before re-coating.
Notes:
1. The paint should be placed in a low temperature, ventilated and dry place; away from fire and heat sources; the shelf life is one year in a cool and dry place.
2. The above information is written based on the actual testing and usage experience of our technical staff, and can be used as a construction guide. However, due to the differences in the coating environment and supporting solutions, it is recommended that users conduct experiments and tests in advance according to actual needs and purposes before confirming use. The company only guarantees the quality and stability of this product itself.
If you have any questions, please contact us promptly and we will answer your questions as soon as possible.